Welcome to the official website of SuZhou Hayxan New Materials Co., Ltd. !

Personal protection and industrial using product development

Major in special fiber selling

Flame retardant

More secure

Service hotline:

188-9671-1679

NEWS

Contact us

SuZhou Hayxan Protection Technology Co.,Ltd.

Tel:188-9671-1679

Contacts:Mr Dong

E-mail:ernest@szhayxan.com

Add: Room 1105 Liuchuan Building C ,NO.209,Zhujiang South Road,Wuzhong District,Suzhou ,Jiangsu Province ,China

News
Your current location: Home > News

2021 China labor protection products fair / Shanghai Labor Protection Exhibition

From April 14 to 16, 2021, the 101st China Labor Protection Products Fair (CIOSH) will meet you in Shanghai New International Expo Center, blowing the industrial spring breeze of the new year.


CIOSH brings together the "labor protection craftsmen" from all over the country. The "labor protection workers" and the "labor protection association" grow together and sing "Chinese craftsmen, labor protection family"! Exhibition scale: covering an area of 70000 square meters, there are more than 2500 exhibitors and more than 50000 visitors. Extreme ingenuity in today's society, while pursuing the immediate benefits brought by "short, flat and fast" and ignoring the soul of product quality, we call for the return of craftsman spirit. Labor protection craftsmen are working hard to improve the product quality from 99% to 99.99%. Their goal is to create the best quality products in the industry that cannot be matched by other peers, and they have a persistent adherence to and pursuit of high-quality products.


In the new year, we are obsessed with the industry and provide the most practical and reliable safety protection for the occupational safety and health industry with more professional services; We unite the industry and provide new sales impetus for tens of thousands of purchasing groups with a more international style; We promote development and build an excellent platform for relevant supporting industries to talk with major brands in the industry from a more diversified perspective.
Time:2021-08-25      Number of Views:791
Testing standards and methods of flame retardant fabrics
What is flame retardant fabric
After special production technology finishing, it can effectively prevent the spread of flame. The textiles after flame retardant finishing will not burn when contacting the fire source, but make the fabrics reduce their flammability in the flame, slow down the speed of spread, and do not form large-area combustion; After leaving the flame, it can quickly self extinguish and no longer burn or smolder. It has good durable washing performance.
The main processes include: THPC (water-soluble flame retardant penetrates into the fiber, turns into polymer after ammonia fumigation chemical reaction, and permanently crosslinks with the fiber), CP (pyrovatex)
American Standard
The National Fire Protection Association has formulated a series of standards for the technical performance of different flame-retardant protective clothing, and nfpa2112 is mainly related to flame-retardant fabrics
NFPA 2112 standard for personal protective flame retardant clothing for industrial use
The flame retardant test adopts the vertical combustion method specified in ASTM d6413 standard, and the materials must meet the following requirements after testing:
The average carbonization length shall not exceed 102 mm. The average afterburning time shall not exceed 2S. There shall be no molten drops after the sample is ignited. For multi-layer materials, each layer needs to be tested separately and pass the above requirements.
Other test contents include:
Indirect HTP (heat transfer performance) ≥ 25j/c ㎡ (6.0 cal/c ㎡) direct HTP (heat transfer performance) ≥ 12.6j/c ㎡ (3.0 cal/c ㎡) thermal shrinkage ≤ 10% flash fire ≤ 50% (exposed area, hands and feet)
EU standard
The EU flame retardant test standards for protective clothing are mainly formulated by the European Technical Commission (cen/tc), and the current standards include EN ISO 11611:2007, EN ISO 11612:2008, and ENISO 14116:2008/ac:2009
En11611:2007 protective clothing for welding and similar processes
The test is carried out in accordance with ISO 15025:2000 standard, including surface combustion and vertical combustion. Depending on the type of material, one or two methods can be selected for testing. For surface burning tests, the material must meet the following requirements:
Any test sample shall not burn and spread to the edge or upper end of the fabric after being ignited. No holes shall be formed after any test sample is ignited. After any test sample is ignited, there shall be no burning droplets or molten objects falling. The average afterburning time must be less than or equal to 2S. The average smoldering time must be less than or equal to 2S.
EN ISO 11611 divides the fire-retardant safety level into class 1 and class 2. The technical indicators of the two levels are the same, and the material must meet the above requirements for surface and bottom combustion.
En11612:2007 protective clothing for workers operating in high temperature environment
This standard has made requirements for the overall performance, structural design, dimensional stability, flame spread, heat resistance and molten metal performance, size mark and shipping mark of the fabric. The flame retardant test method is implemented in accordance with ISO 15025 standard, and the flame retardant performance requirements are consistent with en11611, but EN ISO 11612 standard does not divide the safety level.
Chinese standards
The standard GB 8965.1-2009 for fire protection clothing and welding clothing issued by the General Administration of quality supervision, inspection and Quarantine of the people's Republic of China and the National Standardization Administration of China
Gb8965-1:2009 grade B
The flame retardancy test shall be carried out in accordance with gb/t 5455-1997 vertical combustion method, class B standard requirements
Afterburning time ≤ 2S smoldering time ≤ 2S damage length ≤ 100mm no molten drops allowed
test method
1 vertical method
This test method stipulates that the sample is placed vertically (the length direction of the sample is perpendicular to the horizontal line), the combustion source ignites the sample below the sample, and the minimum ignition time, afterburning time, flame retardancy time, flame spread speed, carbonization length (damage length), carbonization area (damage area) and other indicators related to flame retardancy of the test sample. The vertical burning method is mainly used for flame retardant testing of fabrics such as clothing textiles and curtains.
Common vertical test standards:
Gb/t 5455 textile flammability test
Gb/t 8745 Textiles - Flammability - Determination of surface burning time of fabrics
Ca TB117 California fire retardant test
16 CFR 1615/1616 flammability standard for children's pajamas
245 ° tilt method
This test method stipulates that the sample is placed at an angle of 45 ° (the length direction of the sample forms an angle of 45 ° with the horizontal line), the combustion source is on the upper or lower surface below the sample to ignite the sample, and the time required for the sample to burn upward for a certain distance is measured, or the afterburning, flame retardation time, flame spread speed, carbonization length Indications related to flame retardancy, such as carbonization area or the number of times to contact the flame when measuring the combustion of the sample to a certain distance from the lower end of the sample. The 45 ° tilt method is mainly used for flame retardant testing of carpets and other fabrics.
Common tilt test standards:
Gb/t 14645 flammability of textile fabrics Determination of damage area and number of flame exposure in 45 ° direction
ASTM D 1230 test method for flammability of clothing textiles
NFPA 702 flame retardant standard for California hospital clothing and bedding fabrics
BIFMA interior decoration material test standard
3 Horizontal method
This test method requires that the sample be placed horizontally, ignite at the head end of the sample, measure the spread distance of the flame on the sample and the time it takes to spread this distance, calculate the combustion rate, and use the combustion rate to characterize the flame retardancy of the fabric. The horizontal method is mainly used for the flame retardant test of automotive interior decoration materials.
Common horizontal method test standards:
Fz/t 01028 textile fabrics -- Determination of flammability -- Horizontal method
GB 8410 combustion characteristics of automotive interior materials
Combustion performance of interior decorative materials of fmvss302 (USA) federal transportation vehicles
IEC 60695-11-10 fire hazard test part 11-10: Test Method for 50W horizontal and vertical flames.
Time:2021-08-16      Number of Views:777
2021 China (Shandong) International Textile Expo will open soon
On the morning of June 28, 2021 China (Shandong) International Textile Expo opened at Qingdao International Expo Center. With the theme of "intelligence, fashion, communication and efficiency", the exhibition leads the application and implementation of new equipment, new processes, new materials, new channels and new models in the textile industry through the new digital form of "Exhibition + activity + live broadcast + Forum". It is understood that the Textile Expo is an exhibition supported by the Ministry of Commerce, and it is also a characteristic exhibition brand of "international fashion city construction" in our district. The exhibition will last for three days, with five exhibition halls and an exhibition area of 50000 square meters. It will be divided into five theme exhibitions: sewing equipment exhibition, flour accessories and yarn exhibition, textile printing industry exhibition, clothing supply chain and professional wear industry exhibition, and international leather footwear machinery and materials exhibition, attracting more than 1000 exhibitors. The holding of this exhibition will help textile and garment enterprises increase exhibition opportunities, improve brand image, expand sales channels, drive overall consumption, so that textile and garment upstream and downstream enterprises can quickly find orders through the exhibition platform, accurately match partners, and effectively help local textile and garment enterprises transform and upgrade from old to new drivers.
Time:2021-08-16      Number of Views:865
New fire safety regulations for high-rise civil buildings are coming
The regulations on fire safety management of high-rise civil buildings (hereinafter referred to as the regulations) shall enter into force on August 1. The regulation stipulates that electric bicycles are forbidden in the corridors of high-rise civil buildings, among which seven behaviors related to the safety of owners can be fined up to 10000 yuan. The municipal fire rescue detachment has widely publicized and popularized the new regulations to prevent fire safety accidents.
The top priority is to prevent fire safety and prohibit all kinds of unsafe behaviors. The regulations prohibit unauthorized installation, modification and removal of gas equipment and appliances in violation of the regulations on the safe use of gas. It is forbidden to use liquefied petroleum gas in the underground part of high-rise civil buildings. It is forbidden to produce, store and deal in class A and class B fire hazardous substances in high-rise civil buildings in violation of state regulations. It is forbidden to occupy the cable well, pipe well, or stack sundries in the cable well, pipe well and other vertical pipe wells.
Among them, "no parking of electric bicycles in the corridor" has become a hot topic. The regulations prohibit parking or charging electric bicycles in public halls, evacuation corridors, staircases and emergency exits of high-rise civil buildings. Then, how do residents park their electric bicycles? How to charge? The regulation also gives a solution: "it is encouraged to set up places for centralized storage and charging of electric bicycles in high-rise residential areas. The places for storage and charging of electric bicycles should be set up independently and keep a safe distance from high-rise civil buildings; if it is really necessary to set up in high-rise civil buildings, it should be separated from other parts of the building by fire prevention." "The storage and charging places of electric bicycles should be equipped with necessary fire-fighting equipment, and the charging facilities should have the function of full automatic power-off."
The regulations also clarify the relevant legal responsibilities. The maximum fine for seven acts is 10000 yuan. (1) Carrying out electric welding, gas welding and other open fire operations in high-rise civil buildings, failing to carry out fire approval procedures, make announcements, or fail to implement on-site monitoring measures for fire protection; (2) Outdoor billboards and decorations set up in high-rise civil buildings hinder smoke control and smoke extraction, escape and fire fighting and rescue, or change or damage the fire-proof structure of the building facade; (3) Failing to set suggestive and warning signs for external thermal insulation materials of external walls, or failing to timely repair the damaged, cracked and fallen external thermal insulation system of external walls; (4) Failing to implement the duty system of the fire control room in accordance with the regulations, or arranging personnel who do not have the corresponding conditions to be on duty; (5) Failing to establish full-time fire brigades, volunteer fire brigades and other fire-fighting organizations in accordance with the provisions; (6) The fire-fighting facilities of buildings that need to be stopped due to maintenance are not announced, emergency plans are not formulated, or preventive measures are not implemented; (7) Parking or charging electric bicycles in public halls, evacuation corridors, staircases, and emergency exits of high-rise civil buildings, and refusing to correct.
Time:2021-08-16      Number of Views:702